Dry Electrode Film Solution for Supercapacitors: Process, Equipment and Scale-Up
A practical guide to solvent-free electrode processing, film quality control and production-line planning
Dry electrode processing is attracting growing interest in supercapacitor manufacturing because it removes the solvent-heavy coating and drying route used in conventional wet electrodes. Instead of preparing a slurry, coating it onto a current collector and evaporating the solvent, the dry process blends the active material, conductive additive and binder into a powder, converts that powder into a self-supporting film, and laminates the film onto a current collector.The idea sounds straightforward. In practice, a dry electrode film is not simply a wet electrode with the drying oven removed. Powder flow, binder distribution, fibrillation, film strength, calendering pressure, tension control and collector adhesion all become part of the same process window. A change that improves film strength may reduce pore accessibility. A denser film may lower resistance in one formulation and slow electrolyte wetting in another.
Xiamen TOB New Energy Technology Co., Ltd. (TOB NEW ENERGY) provides dry electrode equipment, supercapacitor electrode preparation systems and complete production-line solutions. Its published dry electrode process is based on mixing active material, conductive agent and binder without solvent, rolling the powder into a film, applying conductive adhesive to the current collector, drying the adhesive layer and laminating the dry film to the foil.
Why dry electrode film is relevant to supercapacitors
The first advantage is the removal of solvent handling from the electrode-forming step. A conventional wet process needs slurry preparation, coating, solvent evaporation, exhaust treatment and often solvent recovery. A dry process does not eliminate every thermal or environmental requirement, but it can reduce the amount of solvent infrastructure tied to electrode fabrication.
That change is especially relevant for supercapacitor electrodes, where high-surface-area carbon materials can produce difficult slurries. Activated carbon, conductive carbon, graphite, carbon nanotubes and other fine powders may demand careful dispersion and drying control in a wet process. A solvent-free powder-to-film route offers another way to build the electrode structure, provided the powder blend can be converted into a mechanically stable film without blocking the pores that the electrolyte must reach.
Dry electrode film processing is most suitable for applications that need one or more of the following:
• reduced solvent use in electrode preparation;
• a shorter route from powder formulation to electrode film;
• high loading or thick-electrode development;
• repeatable film formation for supercapacitor material screening;
• a cleaner transition from laboratory powder processing to pilot-scale continuous equipment;
• process development for cylindrical, prismatic or other supercapacitor formats.
It is not automatically the best choice for every material. A dry formulation must be evaluated for powder flow, binder compatibility, fibrillation behavior, electrical contact, adhesion, flexibility and electrolyte wetting. The decision should be based on the complete electrode and cell performance, not only on the absence of solvent.
The dry electrode film process, from powder to current collector
A practical dry electrode route can be divided into four main stages: dry mixing, binder fibrillation, film forming and calendering or lamination. These stages are closely connected. The material formulation and the equipment settings have to be developed together.
1. Dry mixing: build a uniform powder blend
The process begins with the active material, conductive agent and binder. For a supercapacitor electrode, the active phase may be activated carbon or another high-surface-area carbon material. Conductive additives can include conductive carbon or other electrically conductive powders. PTFE is commonly used as the fibrillating binder in dry electrode development, but the final choice depends on the formulation and the required mechanical and electrochemical properties.
The objective of mixing is not simply to distribute one powder through another. The blend must be uniform enough for the film to have consistent electrical and mechanical behavior across its width. At the same time, the mixing step should avoid damaging the active material, introducing contamination or starting fibrillation too early.
A laboratory dry mixer or high-speed powder mixer should therefore allow control of:
• mixing speed and mixing time;
• addition order;
• vessel loading and fill level;
• temperature rise during mixing;
• powder recovery and cleaning between batches;
• sample collection for composition and dispersion checks.
The formulation should be recorded by mass, lot number and material condition. Fine carbon powders can absorb moisture and behave differently from one batch to another, so powder storage and preconditioning are part of the process rather than an administrative detail.
2. Fibrillation: create the binder network
Fibrillation is the step that gives the dry powder blend a continuous mechanical structure. Under suitable shear and mixing conditions, PTFE binder particles can form fibrils that connect the active material and conductive additive. Those fibrils help the powder hold together as it passes through the film-forming rolls.
The process window is narrow. Insufficient fibrillation may result in a weak film that tears, cracks or breaks during transfer. Excessive shear or over-processing can produce an uneven binder network, change the powder's flow behavior or reduce the accessible surface area of the finished electrode.
Fibrillation should be evaluated through the film rather than by mixer settings alone. Useful checks include film tensile behavior, edge integrity, flexing resistance, particle shedding, thickness uniformity and the appearance of the film after rolling. The correct mixing history depends on the carbon type, particle-size distribution, binder content, moisture condition and equipment geometry.
3. Film forming: convert powder into a continuous sheet
The fibrillated powder is fed into a roller press, where it is compacted to a controlled thickness or density. The result is a free-standing dry electrode film. Depending on the equipment, the film may pass through trimming and winding stages to produce a roll suitable for the next operation.
TOB's published dry electrode film-forming equipment describes a two-horizontal-roll configuration for powder-to-film processing. Its listed parameters include adjustable rolling width, PLC and touch-screen control, adjustable tension and integrated trimming and winding. A published reference for one machine lists a maximum device speed of 10 m/min, rolling precision of up to ±0.0015 mm and pressure-control precision of up to 0.15 T. These are machine references, not universal process targets; the appropriate settings must be validated for each formulation and film thickness.
At this stage, the main engineering task is to maintain a stable relationship between powder feed, roll gap, roll pressure, roll temperature where applicable, line speed and web tension. If powder feeding fluctuates, film basis weight changes. If the roll gap is not parallel, the film becomes thicker on one side. If tension is too high, a weak film may neck or tear. If tension is too low, the web may wander or wrinkle during winding.
4. Calendering and lamination: connect film to the current collector
After forming, the dry film may be rolled again to reach the required thickness, density or surface condition. Calendering should be treated as a separate control step rather than as a simple final pass. It changes the mechanical structure of the film and affects electrical contact, pore accessibility and electrolyte transport.
The current collector is prepared separately. TOB describes a process in which conductive adhesive is coated onto the current collector foil and dried before the dry electrode film and foil are laminated together. This conductive adhesive layer supports contact between the film and the collector without introducing a conventional wet slurry into the active film itself.
A laminating machine for this process needs controlled adhesive coating, drying, alignment, nip pressure, temperature where required and web tension. The final electrode should be checked for delamination, wrinkles, trapped air, exposed collector areas, edge lift and adhesion after winding or cutting.
Equipment and quality-control points
A dry electrode film solution is best specified as a linked equipment set, not as one film-forming machine purchased in isolation.
Laboratory equipment
A laboratory development setup may include:
• precision balance and powder-handling tools;
• laboratory dry mixer or high-speed powder mixer;
• laboratory fibrillation or shear-mixing equipment;
• small dry electrode film-forming machine;
• laboratory roller press for thickness and density adjustment;
• film cutter, slitter or winding unit;
• current-collector cleaning and conductive-adhesive coating tools;
• drying oven for the adhesive layer;
• lamination press or laminating machine;
• thickness gauge, density measurement tools and balance;
• tensile or flexing test equipment;
• electrical resistance and adhesion test methods;
• electrode and supercapacitor testing equipment.
TOB lists a laboratory dry electrode film-forming machine for the powder-to-film process and a dedicated dry electrode film forming machine for battery and supercapacitor applications. It also lists a dry electrode film rolling press and a dry electrode film laminating machine with conductive-adhesive coating. This product combination reflects the actual process sequence: prepare the powder, form the film, adjust the film, coat and dry the collector, and laminate the finished electrode.
Pilot-line equipment
A pilot configuration may add:
• controlled powder feeding and metering;
• larger-capacity high-shear mixing;
• continuous or semi-continuous fibrillation;
• heated or temperature-controlled roller pressing;
• edge trimming and roll winding;
• automatic web guiding and tension control;
• continuous conductive-adhesive coating and drying;
• roll-to-roll lamination;
• slitting and electrode cutting;
• in-line thickness, width and surface inspection;
• roll identification and process-data recording.
The pilot line should not only be faster than the laboratory machine. It must also preserve the material history and quality-control logic developed in the lab. If the lab records only final thickness while the pilot line records tension, pressure, temperature and speed, the two data sets cannot be compared properly.
Quality-control points that deserve attention
Powder blend. Check material identity, moisture condition, particle-size distribution where relevant, blend uniformity and contamination. The powder should flow consistently into the film-forming zone.
Fibrillation. Check whether the film has enough mechanical strength to be handled, trimmed and wound. Inspect for loose powder, weak edges and non-uniform binder distribution.
Film thickness and basis weight. Measure across the width and along the roll. A single centre-point reading can miss edge build-up, roll-gap misalignment or periodic thickness variation.
Density and porosity. Density must be considered together with the intended electrolyte and cell design. A denser film may improve contact but reduce pore accessibility. Porosity should therefore be verified against electrochemical performance rather than selected by thickness alone.
Electrical resistance. Measure film resistance and collector-to-electrode contact resistance. A film can look uniform and still contain poor conductive pathways.
Adhesion and flexibility. Perform peel, bending or handling checks after lamination and after any subsequent rolling or winding. Edge lift is often the first visible sign of an inadequate lamination window.
Electrochemical performance. Test capacitance, equivalent series resistance, leakage current, self-discharge and cycle stability in the intended cell configuration. The dry film is qualified only when the finished supercapacitor meets its target performance.
What changes when the process is scaled up
The move from a few laboratory sheets to a continuous pilot roll changes the problem in several ways.
Powder handling becomes a continuous process
A technician can correct a small laboratory batch by hand. A pilot line cannot rely on that intervention. The powder feed must remain stable over time, and the system must prevent segregation of coarse and fine particles. Hopper design, feeder accuracy, vibration and cleaning become central parts of the process.
Fibrillation history must be transferable
The same nominal mixing speed does not produce the same shear history in a 200 mL vessel and a larger production mixer. Scale-up should compare the relevant material response — film strength, powder flow, electrical behavior and electrode performance — rather than copy rpm alone.
Web tension becomes a product parameter
At laboratory scale, a small film can be supported manually. At pilot scale, the film is a moving web. Unwind tension, roll speed, alignment, trimming, winding tension and roll hardness all affect whether the film survives the line. A stable film-forming recipe can still fail when the winding section stretches or wrinkles the web.
Heat management becomes more important
Dry processing avoids solvent evaporation from the active electrode film, but heat can still be generated by mixing, shear, roll friction, adhesive drying and calendering. Temperature changes the binder behavior, film strength and adhesive condition. Temperature sensors and defined alarm limits should be included before the pilot line is commissioned.
The collector interface is often the scale-up bottleneck
A film that works as a small laboratory coupon may not laminate evenly across a wider collector. Adhesive coating width, drying uniformity, nip pressure, alignment and edge control must be developed together. Lamination trials should include peel strength, electrical resistance, visual inspection and winding or cutting tests.
Data and sampling must expand with the line
A pilot line needs a clear sampling plan. Thickness, basis weight, density, resistance, adhesion and surface condition should be checked at defined intervals across the roll. Each roll should carry a material and process record that links it to the powder batch, equipment settings, operator, date and downstream cell results.
Planning a supercapacitor production line
The final line configuration depends on the cell format, active material, target output and degree of automation. TOB's published supercapacitor production-line information covers cylindrical formats such as 60138, 60130, 38130 and 80180, and lists a broader equipment set including mixer, coater, roller press, slitting machine, winding machine, stacking machine, filling machine, laser sealing machine, formation machine and battery tester.
A practical line can be planned in three stages.
Stage 1: Electrode preparation
For dry electrodes, this section includes powder storage and feeding, dry mixing and fibrillation, powder-to-film forming, film rolling, trimming and winding, collector preparation, conductive-adhesive coating and drying, and lamination. If the same facility also develops wet electrodes, the wet-slurry equipment should be physically separated from the dry-powder route to avoid cross-contamination and confusion in process records.
Stage 2: Cell assembly
The assembly section depends on the supercapacitor format. A cylindrical line may require electrode slitting, separator handling, winding, cell insertion, electrolyte filling, sealing and cleaning. Larger formats may require additional handling, welding, sealing and leak-checking functions. Automatic equipment becomes more valuable as the cell size and output increase, because alignment, filling and sealing errors become expensive after the electrode roll has already been processed.
Stage 3: Formation, grading and testing
Formation and testing should be sized for the planned line output. The test system should support the required charge-discharge current, voltage range, capacitance measurement, equivalent series resistance and cycle-life programme. A line that produces more cells than the testing department can qualify will create a queue rather than useful capacity.
TOB also publishes battery and supercapacitor electrode-preparation laboratory lines, pilot-scale lines and automatic-machine solutions. For a new project, the most practical approach is to define the required cell format and output first, then select the upstream dry-electrode equipment and downstream assembly modules around those requirements.
A sensible route from laboratory to pilot line
The most reliable scale-up path is not to buy the largest available machine at the beginning. It is to establish a material and process window in the laboratory, then carry the same measurements into a pilot line.
A typical development sequence is:
1. qualify the active material, conductive additive and binder combination;
2. establish a mixing and fibrillation window;
3. form small films and measure strength, thickness, density and resistance;
4. laminate the film to the selected current collector;
5. assemble representative supercapacitor cells;
6. measure capacitance, ESR, leakage, self-discharge and cycle stability;
7. identify the parameters that must be controlled continuously;
8. size the pilot feeder, roller, winding, lamination and testing systems;
9. run a controlled pilot campaign with defined sampling and acceptance criteria;
10. transfer the validated process to the intended production-line format.
A dry electrode line is successful when it produces a stable electrode and a stable cell, not merely when the powder passes through the rollers. For supercapacitor manufacturers, the value of the solution lies in connecting powder formulation, film mechanics, collector contact, cell assembly and electrical testing into one traceable process.
About TOB NEW ENERGY
Xiamen TOB New Energy Technology Co., Ltd. supplies battery materials, laboratory equipment, pilot-line equipment and production-line solutions. Its published dry electrode portfolio includes powder-to-film equipment, dry electrode film rolling presses, film-forming machines for battery and supercapacitor applications, and laminating equipment with conductive-adhesive coating.
For supercapacitor projects, TOB provides equipment and line solutions covering electrode preparation, cylindrical supercapacitor assembly, pilot-scale production and testing. The final configuration should be selected according to the active material, cell format, film width, output target, automation level and site utilities.
Contact
Email: [email protected]
Technical support / WhatsApp: +86 181 2071 5609
Website: www.tobmachine.com
- Contact Email
- [email protected]
- Issued By
- XIAMEN TOB NEW ENERGY TECHNOLOGY CO., LTD.
- Website
- TOB NEW ENERGY
- Phone
- +86 18120715609
- Business Address
- Building 5th, NO.1633, Jicheng Road, Tong'an torch Industry Phase II, Tong'an District, Xiamen City, Fujian Province, China
- Country
- China
- Categories
- Energy
- Last Updated
- November 18, 2026
Disclaimer: This press release was submitted by a registered PRFree contributor and has not been verified or endorsed by PRFree. PRFree assumes no responsibility or liability for its accuracy, content, legality, or reliability. The contact email for this release can be viewed here. See our Disclaimer.