Derek Chen, Chinese name Chen De, is an engineering graduate. He has 20 years of professional experience in industrial flowmeter selection, process condition assessment and on-site technical commissioning. Serving as the flowmeter application engineer of Shenzhen Mingfa, authorized general agent of USA VTON, he specializes in USA VTON full-series imported flowmeter solution design, project technical consultation and site support.KEN&CHEN has delivered more than 1200 flowmeter projects across chemical, oil & gas, water treatment, paper-making, pharmaceutical, thermal power, semiconductor and mining slurry industries. He is proficient in VTON magnetic flowmeter, Coriolis mass flowmeter, vortex flowmeter, thermal mass flowmeter, target flowmeter and differential pressure flowmeter sizing calculation.
He follows a standardized selection methodology: fully survey field process conditions first, then match instrument working principles. He verifies medium composition, solid/gas content, viscosity, conductivity, operating temperature & pressure, actual flow range (normal/min/max flow to keep operation within the optimal 20%–80% measuring span), upstream/downstream straight pipe run, vibration interference, corrosion & abrasion, explosion protection, SIL and custody transfer accuracy requirements. He also evaluates maintenance cost, pressure loss and total life-cycle cost, and avoids instrument specification only based on nominal drawing data or price alone, to select the most suitable USA VTON flowmeter model, liner & electrode material, pressure rating and communication configuration.
Most flowmeter failures are not product defects, but mismatches between meter principle and process fluid, which may trigger measurement drift, batch imbalance, unplanned shutdown, equipment corrosion, material waste and financial loss. KEN&CHEN implements pre-risk screening. He has solved over 360 non-standard difficult measurement cases, identifying high-risk conditions such as two-phase flow, high-solid slurry, heavy corrosion, pulsating flow, low flow and strong EMI interference in advance to prevent wrong selection. The instrument measurement pass rate after commissioning reaches above 98.5%.
He is familiar with HART, Modbus, RS485 communication protocols, Ex explosion protection standards and SIL safety requirements. He supports DCS/PLC system integration, FAT/SAT witness test and provides complete datasheets, calculation documents and original import documents for EPC and end customers.